On capability of different FACTS devices to mitigate a range of power quality phenomena
“ توانایی دستگاههای مختلف FACTS در کاهش تعدادی از پدیدههای کیفیت توان” می باشد
که مربوط به سال 2016 و شامل 10 صفحه فایل انگلیسی
20 صفحه فایل ترجمه فارسی تعداد کلمات فارسی: 4144
a b s t r a c t
This study investigates the impact of different flexible AC transmission system (FACTS) devices on critical power quality (PQ) phenomena including voltage sags, harmonics and unbalance from the perspective of both mitigation effect and potential negative impact. The FACTS devices, including static VAR compensator, static compensator (STATCOM) and dynamic voltage restorers, are modelled in commercially available software Power Factory/DIgSILENT to study their impacts on the critical PQ phenomena. Two control strategies, voltage regulation and reactive power compensation, are considered for STATCOM. For DVR, a PI-controller is developed for the purpose of voltage sag mitigation. The merit of the proposed controller is presented by the dynamic response of during fault voltage and the capability of post-fault voltage recovery. The study is carried out on a large-scale generic distribution network. The impact of various devices on PQ phenomena is assessed using appropriate evaluation methodologies, and the results obtained with and without mitigation are presented and compared using
heatmaps.
چکیده
این مقاله، به بررسی تأثیر دستگاههای مختلف سیستمهای انعطافپذیر AC (FACTS) بر روی پدیده بحرانی کیفیت توان (PQ) شامل : افت ولتاژ، هارمونیک و عدم تعادل از دیدگاه هر دو اثر کاهش و تأثیر منفی بالقوه میپردازد. دستگاه FACTS، ازجمله جبرانکننده استاتیک VAR، جبرانکننده ایستا (STATCOM) و ترمیمکنندههای ولتاژ دینامیکی، در نرمافزار تجاری Power Factory / Dig SILENT مدلسازی میشود تا تأثیرات آن بر پدیدههای PQ بحرانی را مطالعه کنند. دو استراتژی کنترل، تنظیم ولتاژ و جبران توان راکتیو برای STATCOM در نظر گرفتهشده است. برای DVR یک کنترلکنندهPI برای کاهش افت ولتاژ طراحیشده است. کارایی کنترلکننده پیشنهادی با پاسخ دینامیکی ولتاژ خطا و توانایی بهبود ولتاژ پس از خطا ارائهشده است. این مطالعه بر روی یک شبکه توزیع عمومی مقیاس وسیع انجام میشود. تأثیر دستگاههای مختلف بر روی پدیدههای PQ با استفاده از روشهای ارزشیابی مناسب ارزیابی شد و نتایج بهدستآمده با و بدون کاهش مقادیر ارائهشده و با استفاده از نقشههای حرارتی مقایسه میشوند.
دانلود رایگان مقاله انگلیسی

توضیحات محصول
On capability of different FACTS devices to mitigate a range of power quality phenomena
“ توانایی دستگاههای مختلف FACTS در کاهش تعدادی از پدیدههای کیفیت توان” می باشد
که مربوط به سال 2016 و شامل 10 صفحه فایل انگلیسی
20 صفحه فایل ترجمه فارسی تعداد کلمات فارسی: 4144
a b s t r a c t
This study investigates the impact of different flexible AC transmission system (FACTS) devices on critical power quality (PQ) phenomena including voltage sags, harmonics and unbalance from the perspective of both mitigation effect and potential negative impact. The FACTS devices, including static VAR compensator, static compensator (STATCOM) and dynamic voltage restorers, are modelled in commercially available software Power Factory/DIgSILENT to study their impacts on the critical PQ phenomena. Two control strategies, voltage regulation and reactive power compensation, are considered for STATCOM. For DVR, a PI-controller is developed for the purpose of voltage sag mitigation. The merit of the proposed controller is presented by the dynamic response of during fault voltage and the capability of post-fault voltage recovery. The study is carried out on a large-scale generic distribution network. The impact of various devices on PQ phenomena is assessed using appropriate evaluation methodologies, and the results obtained with and without mitigation are presented and compared using
heatmaps.
چکیده
این مقاله، به بررسی تأثیر دستگاههای مختلف سیستمهای انعطافپذیر AC (FACTS) بر روی پدیده بحرانی کیفیت توان (PQ) شامل : افت ولتاژ، هارمونیک و عدم تعادل از دیدگاه هر دو اثر کاهش و تأثیر منفی بالقوه میپردازد. دستگاه FACTS، ازجمله جبرانکننده استاتیک VAR، جبرانکننده ایستا (STATCOM) و ترمیمکنندههای ولتاژ دینامیکی، در نرمافزار تجاری Power Factory / Dig SILENT مدلسازی میشود تا تأثیرات آن بر پدیدههای PQ بحرانی را مطالعه کنند. دو استراتژی کنترل، تنظیم ولتاژ و جبران توان راکتیو برای STATCOM در نظر گرفتهشده است. برای DVR یک کنترلکنندهPI برای کاهش افت ولتاژ طراحیشده است. کارایی کنترلکننده پیشنهادی با پاسخ دینامیکی ولتاژ خطا و توانایی بهبود ولتاژ پس از خطا ارائهشده است. این مطالعه بر روی یک شبکه توزیع عمومی مقیاس وسیع انجام میشود. تأثیر دستگاههای مختلف بر روی پدیدههای PQ با استفاده از روشهای ارزشیابی مناسب ارزیابی شد و نتایج بهدستآمده با و بدون کاهش مقادیر ارائهشده و با استفاده از نقشههای حرارتی مقایسه میشوند.
دانلود رایگان مقاله انگلیسی